Back

Cogent Real-Time Systems Inc.
Patches for Cogent DataHub V10 x64
Windows
4 patches available
DataHub® software integrates data from a number of data sources and provides the only secure way to move industrial data from OT to IT without requiring any inbound firewall ports or VPNs. DataHub is unmatched for versatility, power, speed, security, and ease of use.
Cogent DataHub V10 x64 Version 10.0.8
Release Date
7/7/2025
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-2059] – Cannot write to a sparkplug metric with certain configurations$$$[DATAHUB-2072] – V10 Remote Config login fails with cryptic error when trying to connect to V11$$$[DATAHUB-2075] – OPC UA server sometimes produces the wrong types for folders$$$[DATAHUB-2076] – OPC UA client connection does not preserve certificate password settings.$$$[DATAHUB-2104] – Remote Config does not show the correct list of security policies and modes for a UA server$$$[DATAHUB-2129] – Cannot change “log to file” options in Remote Config event log$$$[DATAHUB-2132] – DataHub crash when loading an OPC configuration created by V6.4$$$[DATAHUB-2134] – MQTT broker stops accepting connections after a malformed Sparkplug message$$$[DATAHUB-2135] – Remote Config writes a log file that it should not$$$[DATAHUB-2136] – Write to PI Historian fails if any value cannot be converted to PI type$$$[DATAHUB-2143] – Sparkplug application cannot write to metrics with # or + in the name$$$[DATAHUB-2144] – Permissions fail when a client subscribes to Sparkplug points while Sparkplug is disabled in the broker$$$[DATAHUB-2149] – PI external historian connection writes boolean with the wrong type.$$$[DATAHUB-2158] – Crash when an ODBC transaction produces a long error message$$$[DATAHUB-2160] – OpcUaSupport.g method AddMethod()third argument does not interpret path strings$$$[DATAHUB-2162] – Remote Config runs out of memory when script log is paused$$$[DATAHUB-2163] – Some attempted writes from the MQTT broker are ignored$$$[DATAHUB-2169] – MQTT client over-counts subscriptions and generates an error$$$[DATAHUB-2171] – Memory leak when stopping a Gamma ODBC thread$$$[DATAHUB-2172] – Advanced parser PointNameModifier function is not applied.$$$[DATAHUB-2179] – OPC A&E server disconnects a client if more than 50;000 conditions are all defined at once.$$$[DATAHUB-2181] – WebView color palette control is visible in Kiosk mode$$$[DATAHUB-2182] – Branch points occasionally show as value points in the data viewer$$$[DATAHUB-2188] – OPC A&E attributes are not always generated correctly$$$[DATAHUB-2190] – OPC UA A&C alarms fail with item IDs with colons in the name$$$[DATAHUB-2191] – Possible crash when tunnel fails due to permission denial.$$$[DATAHUB-2192] – Invalid WebSocket key sent when tunnelling$$$[DATAHUB-2193] – Possible crash when shutting down a processing thread$$$[DATAHUB-2224] – set_canonical command does not work correctly from a cfg file$$$[DATAHUB-2231] – Bridges set by Remote Config do not propagate their canonical types from the source to the destination$$$[DATAHUB-2232] – MQTT broker sometimes rejects a connection with “PROTOCOL” error$$$[DATAHUB-2234] – OPC UA connections are not always cleaned up when a subscription or session fails during initialization.$$$[DATAHUB-2243] – MQTT client does not transmit items that do not exist at connection time$$$[DATAHUB-2244] – MQTT broker sends messages for uninitialized points$$$[DATAHUB-2247] – OPC UA client sends large message when reading engineering units$$$[DATAHUB-2254] – AVEVA PI external historian cannot write after tunnelling store and forward$$$[DATAHUB-2256] – Gamma freeze_writes does not remember the “force” flag$$$[DATAHUB-2269] – Cannot import a Modbus configuration from CSV$$$[DATAHUB-2274] – Data viewer in Remote Config not displaying data correctly$$$[DATAHUB-2277] – OPCAddItem2 command returns wrong exit code when adding the same item twice$$$[DATAHUB-2279] – DCOM AppID is set incorrectly in some cases$$$[DATAHUB-2282] – HDA Classic external historian client generates a duplicate dictionary key error$$$[DATAHUB-2284] – PI Historian write fails when duplicate point is selected$$$$$$DataHub Improvements:$$$$$$[DATAHUB-2196] – Remove the Advanced button from OPC UA A&C configuration$$$[DATAHUB-2210] – Add an option to tunnels to reconnect periodically in data diode mode$$$[DATAHUB-2228] – Allow branches to act as redundancy switch points$$$[DATAHUB-2236] – Adjust lifetime and keepalive times on OPC UA connections$$$[DAT
Cogent DataHub V10 x64 Version 10.0.7
Release Date
7/5/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-2063] – Selected points in external historian are not shown in Remote Config$$$[DATAHUB-2066] – Arrays in OPC UA always have bad quality$$$[DATAHUB-2067] – MQTT broker does not work if MQTT client is not installed
Cogent DataHub V10 x64 Version 10.0.7
Release Date
7/5/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-2063] – Selected points in external historian are not shown in Remote Config$$$[DATAHUB-2066] – Arrays in OPC UA always have bad quality$$$[DATAHUB-2067] – MQTT broker does not work if MQTT client is not installed
Cogent DataHub V10 x64 Version 10.0.6
Release Date
7/5/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-2063] – Selected points in external historian are not shown in Remote Config$$$[DATAHUB-2066] – Arrays in OPC UA always have bad quality$$$[DATAHUB-2067] – MQTT broker does not work if MQTT client is not installed
Cogent DataHub V10 x64 Version 10.0.4
Release Date
4/12/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-1673] – SQLite query could produce fatal exception if lock times out$$$[DATAHUB-1797] – Notification plugin generates ACK points with GUIDs for names$$$[DATAHUB-1807] – OPC UA can reverse the order of incoming messages in rare cases$$$[DATAHUB-1809] – MQTT advanced parser does not recover after an invalid message$$$[DATAHUB-1811] – The S-Sharp ASP processor does not accept single-quotes in the literal portion of the document$$$[DATAHUB-1813] – Sparkplug application is sending an incomplete rebirth request$$$[DATAHUB-1819] – The “read” command responds with a garbage message on some errors.$$$[DATAHUB-1820] – WebSocket can connect and push data without Connectivity.Connect permission$$$[DATAHUB-1823] – Remote Config Tunnel: changing Data Flow Direction does not change rest of Radio Buttons accordingly$$$[DATAHUB-1824] – Notification scripts are run too frequently in some configurations$$$[DATAHUB-1833] – Import of tag names from CSV file fails when “Split point names on character” is disabled$$$[DATAHUB-1838] – Status updates fail in External Historian and InfluxDB in Remote Config if MQTT is not installed$$$[DATAHUB-1839] – Point picker not disabled in External Historian when forwarding is enabled$$$[DATAHUB-1840] – Changing a forwarding strategy in Remote Config requires restart of DataHub$$$[DATAHUB-1844] – MQTT Broker throwing exception and crashing when invalid input is published$$$[DATAHUB-1852] – Attaching an OPC UA application certificate does not persist through Remote Config$$$[DATAHUB-1863] – Notification states ignoring “only trigger on good quality” flag – potentially breaking change$$$[DATAHUB-1864] – OPC UA does not preserve node description from external UA servers$$$[DATAHUB-1865] – MQTT sampling not using window size correctly – potentially breaking change$$$[DATAHUB-1866] – DLL signature should be valid even though the signing certificate has expired$$$[DATAHUB-1867] – OPC UA server endpoint should not be case sensitive$$$[DATAHUB-1870] – Point names with + and # produce illegal MQTT topic names$$$[DATAHUB-1873] – Authentication fails for HTTP notifier and PI Historian$$$[DATAHUB-1874] – Some functions fail when the computer name contains non-ASCII characters$$$[DATAHUB-1887] – Cannot delete stored bridge transforms in Remote Config$$$[DATAHUB-1888] – Store & Forward cache directory button does not function in RC$$$[DATAHUB-1890] – RC crash when DH disconnects and then refresh RC$$$[DATAHUB-1895] – 10.0.4 is crashing from unsuccessful OPC DA client connection$$$[DATAHUB-1897] – New Script dialog unusable in Remote Config$$$[DATAHUB-1899] – Add a limiter to the MQTT broker to avoid a never-ending event loop when busy$$$$$$DataHub Improvements:$$$$$$[DATAHUB-1682] – DataHub should automatically use a new certificate when the certificate file changes on disk$$$[DATAHUB-1692] – Upgrade MQTT library to Mosquitto V1.6.15$$$[DATAHUB-1694] – Make engineering units and description available to MQTT$$$[DATAHUB-1795] – Add sorting to the lists in the OPC UA Server Status dialog$$$[DATAHUB-1800] – Add client information to the MQTT advanced parser$$$[DATAHUB-1801] – Upgrade Grafana to version 8.3.3$$$[DATAHUB-1802] – If A&C receives an unknown event type; treat the event as BaseEventType instead of ignoring the event$$$[DATAHUB-1803] – Make points from decomposed MQTT messages available as individual MQTT topics$$$[DATAHUB-1806] – Change the MQTT broker to override the SSL cipher list from the registry$$$[DATAHUB-1818] – Discard unrequested OPC DA keepalive messages instead of signaling an error$$$[DATAHUB-1821] – Setting the Sparkplug data point prefix to a colon splits the Sparkplug hierarchy into one domain per group$$$[DATAHUB-1825] – Allow alarm acknowledgements even when the alarm does not require it$$$[DATAHUB-1843] – Add a point to an A&E domain that indicates whether the connection is currently established$$$[DATAHUB-1850] – Add an option to OPC UA A&C to append the node ID to condition name$$$[DATAHUB-1869] – Improve perform
Cogent DataHub V10 x64 Version 10.0.3
Release Date
10/26/2023
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

DataHub Bugs Fixed:$$$$$$[DATAHUB-1602] – Web Server does not (re-)initialize properly when deleting licenses triggers switch to demo mode$$$[DATAHUB-1631] – Null reference exception when removing a full license$$$[DATAHUB-1708] – Missing timestamp and bdSeq members in Sparkplug NBIRTH messages$$$[DATAHUB-1725] – OPC A&E does not correctly update filters when you change them in a running connection$$$[DATAHUB-1726] – OCS4D error when launch WV from RC$$$[DATAHUB-1729] – WebView logins could produce a spurious error in the script log$$$[DATAHUB-1730] – Scripting crash calling open() with an invalid file mode$$$[DATAHUB-1732] – DataHub service crashes during STOP$$$[DATAHUB-1733] – Alarm events from pedantic UA A&C servers (Siemens S7) are ignored$$$[DATAHUB-1734] – A&C event is ignored if the A&C server sends a null comment or message field$$$[DATAHUB-1740] – MQTT advanced parser publish preview does not understand pathData$$$[DATAHUB-1741] – GetChildren internal call returns a null value for the first child$$$[DATAHUB-1743] – MQTT advanced parser editor in Remote Config does not contain common functions list$$$[DATAHUB-1744] – Tunnels do not enforce their maximum message length$$$[DATAHUB-1746] – MQTT broker does not recognize + as a wildcard at the end of a topic$$$[DATAHUB-1751] – MQTT publishes topics for valueless branch points$$$[DATAHUB-1753] – External historian configuration can be corrupted when written$$$[DATAHUB-1761] – OPC UA server crashes due to thread race with multiple clients connecting and disconnecting$$$[DATAHUB-1763] – DataHub does not update the value when a new canonical type is set on a point$$$[DATAHUB-1764] – Funky placement of DataHub gear icon on taskbar$$$[DATAHUB-1766] – MQTT broker rejects subscriptions for topics beyond 200 characters$$$[DATAHUB-1767] – MQTT advanced parser default Publish does not work if no Receive schema is defined$$$[DATAHUB-1770] – OPC UA server rejects connections when client certificate contains unexpected fields$$$[DATAHUB-1771] – MQTT client sends branch points in snapshot mode$$$[DATAHUB-1773] – Binary message encoding may cause a crash for point names above 128 characters$$$[DATAHUB-1779] – MQTT client skips messages when the socket becomes full$$$[DATAHUB-1782] – Remote Config crashes when dealing with an OPC UA CSV file with duplicate entries$$$[DATAHUB-1783] – MQTT client does not drop a point that cannot be transmitted due to broker message length limit$$$[DATAHUB-1789] – MQTT client does not honor the Maximum Update Rate setting$$$[DATAHUB-1793] – Database native interface has a drawing glitch$$$[DATAHUB-1794] – A&C methods (ack; confirm; etc.) are missing from browse results$$$$$$DataHub Improvements:$$$$$$[DATAHUB-1625] – Add a stateless OPC A&E event type to notifications$$$[DATAHUB-1684] – Produce an understandable error when a historian is configured to forward from itself$$$[DATAHUB-1685] – Eliminate the DLL approval step in RC and WebView if the DLLs are properly signed$$$[DATAHUB-1727] – Add string manipulation functions to Notification and MQTT advanced parser$$$[DATAHUB-1731] – Add the ability to save the script log to a file$$$[DATAHUB-1742] – Add a GetChildren call to S-Sharp code when creating ASP in the MQTT advanced parser$$$[DATAHUB-1745] – Add the ability to send byte arrays to a socket using the .NET API$$$[DATAHUB-1747] – Web application manager does not store its configuration until it exits$$$[DATAHUB-1750] – Add a script function to the MQTT advanced parser to get a list of registered points$$$[DATAHUB-1752] – Add commands to the External Historian to allow script access$$$[DATAHUB-1754] – Change the label of Primary application ID in Sparkplug client interface$$$[DATAHUB-1755] – Add an option to set the token lifetime in Google IoT / Clearblade connections$$$[DATAHUB-1769] – Change the way numbers are coerced to DATE type$$$[DATAHUB-1774] – Add support for BitConverter to S-Sharp scripting$$$[DATAHUB-1775] – Change S-Sharp mapping of “Array” from Listto Array$$$[DATAHUB-1780] – Improve MQT