8 patches available
Nx Witness Desktop Client – A thick client that runs on Windows, Ubuntu Linux and macOS that allows users to connect to, view live and recorded video, and manage Nx Witness system configurations.
Nx Witness Client x64 Version 6.0.1.39873
Release Date
11/12/2024
Bug Fix?
Yes
Minor Release?
No
Patch Notes

6.0.1.39873 Video Management System$$$PUBLISHED 12 Nov 2024$$$Release Notes:$$$BREAKING CHANGES:$$$Support for Raspberry Pi 3 is discontinued.$$$Support for Ubuntu 18.04 will be discontinued in the next major release (6.1).$$$Support for Raspberry OS 10 will be discontinued in the next major release (6.1).$$$OPERATING SYSTEMS/PLATFORMS:$$$Added support for Ubuntu 24.04.$$$GENERAL IMPROVEMENTS:$$$JPG is set as the default format when saving screenshots as it is a few times smaller than PNG.$$$Improved settings of the Mute action: add the Alt + U hotkey and a button for local media files$$$Added the Mute incoming sound button for the layout items. It is enabled if the Play audio from all cameras on layout local setting is enabled.$$$Once the sound is played on an item on the layout; the corresponding item will highlight.$$$On NXE VCA Cameras; the ROI config was not applied after camera restart. Fixed.$$$Improved the hardware acceleration device selection algorithm if a PC has multiple video adapters.$$$ANALYTICS IMPROVEMENTS / FIXES:$$$IPCAM Cameras now work with the Milesight Analytics Plugin.$$$Alibi Cameras now work with the Uniview Analytics Plugin.$$$Face recognition did not work for Hikvision cameras. Fixed.$$$Analytics Object Detected rules were not properly triggered if the attributes contained the Allow / Deny lists. Fixed.$$$DEVICE SUPPORT AND FIXES:$$$Devices Specific Fixes:$$$Fixed PTZ issues on Hikvision DS-2ZMN2507C-HT; DS-2CD6D55G2-IZHS.$$$Dual-Streaming was disabled on Aiphone Video Door Station IX-DV$$$Hikvision DS-2DE4225IW-DE was detected as a regular ONVIF camera with Hikvision specific capabilities unavailable. Fixed.$$$Truvision TVLP-S01-0402-BULx is detected as Hikvision to enable Hikvision-specific features.$$$The Axis TU9002 joystick is now supported on Ubuntu.$$$Fixed streaming issues on the FLIR AI series cameras.$$$Fixed issues with Optex Lidar cameras.$$$The Axis 2N SIP Horn speaker did not initialize properly. Fixed;$$$Stream from Aira Tablets did not show up in the Desktop Client. Fixed.$$$Server did not use the H.265 profile on Honeywell cameras. Fixed.$$$Server could reset time settings on Hikvision cameras after addition or Server restart. Fixed.$$$Newly Supported Devices:$$$The Axis TU9002 joystick is now supported on Ubuntu.$$$Encoders added to the analog list:$$$Dahua NVR608H$$$Axis M71xx$$$Uniview UV-XVR301x$$$Multisensor Cameras:$$$Hikvision DS-2SF8C442MX; DS-2TD4137-25/WY; DS-2SE7C432MW-AEB; DS-2TD4136x$$$Avigilon 15C-H4A-3MH-180; CAM 2-2 6.0C-H5DH-DO1-IR$$$Dahua BF1241$$$Hanwha PNM-9085$$$Milesight MS-C5321-FPE; NC5321-FPE$$$Axis P3735PLE; P47x$$$Advanced PTZ:$$$Bolin Technology EXU248F; EXU230NX; EXU420N$$$BUG FIXES:$$$General Fixes$$$With the “Keep camera stream and profile settings” options enabled; if the configured profile was removed from the Camera web page; Server stopped getting the corresponding stream. Now Server changes the video profile to a default one in this case.$$$Server could change time on some cameras even if the Allow System to optimize Camera Settings option was disabled. Fixed.$$$UI Fixes:$$$After merging Systems; Cloud connection metrics in Web Admin on Linux server were shown incorrectly. Fixed.$$$After the failover occurred; streams from the devices which were switched to another Server did not show up in the Desktop Client (the recording still worked fine). Fixed.$$$The Desktop Client stopped playing sound on the Layout item when a zoom window was created. Fixed.$$$Cloud layouts (Shared layouts) were not properly displayed after saving. Fixed.$$$Administrators could not modify group membership/permissions for some Cloud accounts. Fixed.$$$When using hotspots; streams from devices could flip upside down. Fixed.$$$API/SDK UPDATES:$$$All API and SDK changes are reflected in the Meta Release Notes available here:$$$https://gitlab.nxvms.dev/dev/meta_vms_evolution/-/blob/6.0.1_R1/meta_release_notes.md?ref_type=heads&plain=1$$$HANWHA ONLY:$$$On some Hanwha cameras (i.e. XND-6085V); ROI area configured in the Desktop C
Nx Witness Client x64 Version 6.0.0.39503
Release Date
9/5/2024
Bug Fix?
Yes
Minor Release?
No
Patch Notes

6.0.0.39503 Video Management System$$$PUBLISHED 05 Sep 2024$$$Release Notes:$$$SUMMARY:$$$Release Notes show changes relative to the latest official release (5.1.5.39242).$$$NEW FEATURES:$$$Improved and redesigned user management with group-applied permissions:$$$User management UI design was significantly reworked and improved.$$$User rights system has been enhanced:$$$Assigning a single user or group unique permissions to selected cameras is now possible.$$$A user can be a member of multiple permission groups.$$$Groups can inherit permissions from other groups.$$$Enhanced LDAP Integration:$$$VMS continuously synchronizes users and groups with LDAP.$$$LDAP Groups can be imported to VMS as well as a user membership in those groups; and it is possible to configure permissions for those groups in VMS.$$$Deployed new LDAP Sync Issue Event and added support to Desktop Client.$$$A new user type (Temporary) is introduced:$$$Temporary Users can only use the Desktop Client / Web Admin but cannot use Cloud Portal.$$$Temporary Users are limited to Viewer Group Permissions and cannot access Secure APIs.$$$The ability to follow objects of interest with Camera Hotspots and Camera Linking is introduced.$$$NVidia hardware video decoding acceleration implemented on the Desktop Client running on Windows and Ubuntu.$$$Emails from VMS can now be sent through the Cloud SMTP Server; which facilitates SMTP Email setting a lot.$$$BREAKING CHANGES:$$$Support for Microsoft Windows 8.1 and Microsoft Windows Server 2012 is discontinued.$$$Support for Ubuntu 18.04 will be discontinued in the next major release (6.1).$$$Support for Raspberry Pi 3 will be discontinued in the next minor release (6.0.x).$$$Support for Raspberry OS 10 will be discontinued in the next major release (6.1).$$$NEW OPERATING SYSTEMS SUPPORTED:$$$MacOS 14.0.$$$Raspberry Pi OS 11 (32-bit).$$$Raspberry Pi OS 12 on Raspberry Pi 3 and Raspberry Pi4 (32-bit) without support for native Raspberry cameras.$$$IMPROVEMENTS:$$$New calendar provides efficient navigation across large archives and timeframes.$$$WebRTC is greatly improved. More details will be provided in the separate API release notes.$$$DST Support is greatly improved.$$$JWT Tokens are supported. This should eliminate issues with the Cloud DB performance and logout.$$$Webpages and Integrations have been separated in the Main Menu.$$$Logs configuration and extraction functionality is greatly improved in the Desktop Client.$$$The look and feel of the Desktop Client is redesigned to match the modern design requirements and be ready to implement for future design changes.$$$The maximum number of cameras per server is increased to 256. Note that the performance and stability of the system depend on the server hardware.$$$SECURITY:$$$Bulk approval for Self-Signed certificates is enabled.$$$Administrators now cannot change certain advanced system settings through WebAdmin. Now all settings are available to the owner only.$$$Client-Server API communication is switched to a more secure protocol.$$$Trusted Man in the Middle (MITM) certificates are supported by the Desktop Client.$$$New user sessions are now logged in the Audit Trail.$$$The User Manual is updated.$$$User Manual on Linux opens up in the internal browser window instead of the system default browser.$$$The Desktop Client Welcome screen can be configured to hide systems found through auto-discovery.$$$The background image size limitation within the Desktop Client is removed.$$$In-Client Browser (Webkit) has been updated.$$$The Desktop Client retains the last screenshot export settings as the default for future screenshot exports.$$$The Camera Settings Tab is optimized to lower the CPU load.$$$The Storage Management Dialog now provides automatically refreshed capacity data in place of a manual refresh process.$$$The Email address is not set notification is removed from the Desktop Client.$$$Added double-click option to select current user and system in the resource tree.$$$During video playback; the Desktop Client will rewind
Nx Witness Client x64 Version 5.1.5.39242
Release Date
8/5/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

5.1.5.39242 Video Management System$$$PUBLISHED 05 Aug 2024$$$Release Notes:$$$These release notes cover changes implemented since the latest minor release (5.1.4.38559).$$$BREAKING CHANGES:$$$Support for Microsoft Windows 8.1 and Microsoft Windows Server 2012 will be discontinued in the next major release (6.0/Gen6).$$$Support for Raspberry Pi 3 will be discontinued in the next Gen6 minor release (6.0.x).$$$GENERAL IMPROVEMENTS$$$Improved stability when the network connection between System components is poor.$$$ANALYTICS IMPROVEMENTS / FIXES:$$$Improved notifications and event management with GANZ cameras.$$$Bookmark search by tags is improved.$$$Dahua ITC413 is updated to support traffic detection events.$$$Dahua LPR models updated for recent firmware changes.$$$On Hikvision DS-2CD2687G2HT-LIZS; the motion events were triggered instead of intrusion detection or line crossing; causing recording issues. Fixed.$$$Hikvision DS-2CD2047G2H-LIU devices did not detect vehicles. Fixed.$$$DEVICE SUPPORT AND FIXES:$$$Newly Supported Devices:$$$Elmo PROIDF30D; PROIDF31D; PROIBF30D; PROIBF31D; PROIBF32D; PROIBF33D; PROIBF34D; PROIBF35D; PROIBF36D; PROIBF37D.$$$LTS - VSPTZIP4C44WSL.$$$Digital Watchdog | N8PC-OLAH4.$$$Osiris OS-I3-EENS8M-MST.$$$Hikvision DS-QAZ1325G1T Network Speaker.$$$Axis P3738-PLE.$$$Encoders added to the analog list:$$$Mazi HAVR-08LT.$$$Multisensor Cameras:$$$Hikvision DS-2TD4137; DS-2DE3A404IWG. DS-2CD6D44G1H; DS-2SE7C144IW.$$$Raysharp CT252N6TNB.$$$Uniview UV-IPC94144SR; TIC2621SR-F3-4F4AC-VD.$$$Digital Watchdog TB2XTH36IP5.$$$Arecont Vision AV32576RSIR.$$$Advanced PTZ:$$$i-PRO WV-X66300-Z3/Z3L; WV-X66300-Z4/Z4L; WV-X66600-Z3/Z3L; WV-X66700-Z3/Z3L.$$$Dahua SD5A225XAN-HNR; SD6C3425GB-HNR-A-PV1; IP-2PT-4IZ25B; SD49425GB.$$$Pelco Spectra Enhanced D6230.$$$Hikvision DS-2SF8C442MXG-ELW.$$$Devices Specific Fixes:$$$Zenitel Intercom:$$$Zenitel TCIS-3 device experienced interrupted audio when viewed in the Desktop Client. Fixed.$$$Zenitel TMIS-1 and TCIS-3 digital input events and audio were delayed in the Desktop Client. Fixed.$$$Axis:$$$The secondary stream of an Axis M2036-LE camera was not set when multiple devices were present. Fixed;$$$Axis P3719PLE camera displayed intermittent recording of an H.265 stream. Fixed.$$$Axis C1310E devices toggle between online and offline state. Fixed.$$$Axis D3110 was recognized as a camera when only outputs were configured. Fixed.$$$Axis P8221 I/O module displayed an ‘unauthorized’ error message when the correct credentials were provided. Fixed.$$$Bosch$$$Bosch Dinion 5100 iR was not discovered but can be added. Fixed.$$$Fixed interrupts in recording on Bosch DINION 7100i.$$$Fibaro intercoms did not stream MJPEG over HTTP after manual addition. Fixed.$$$Hikvision iDS-6716HUHI-M NVR supports Onvif PTZ.$$$Some ONVIF input events from Digital Watchdog cameras were not logged by the Server; Fixed.$$$Some Vivotek cameras with new firmwares could not be authenticated after reboot. Fixed.$$$Fixed dual-streaming issues with Amcrest IP4M-1082E.$$$Video imported from Lilin Z3R8922H camera was not added to the archive. Fixed.$$$On Dahua X82B3A NVR; not all channels were properly discovered. Fixed.$$$BUG FIXES:$$$If a Camera Recording action was set up with pre-recording time on a source camera; the actual pre-recording time was incorrect. Fixed.$$$Bookmark filtering by tags did not work if a tag contained the # symbol. Fixed.$$$On large storage arrays (60TB+); the data could take up all the space ignoring the “Reserve space” value. Fixed.$$$On network disconnection failover; the fallback Server took over all the cameras within the system before releasing all cameras to their original Servers. Fixed.$$$Server would repeat actions or duplicate notifications for One-time Analytic Object triggers. Fixed.$$$The Push My Screen option was missing for newly created Video Walls. Fixed.$$$Non-admin users did lose the ability to view a camera in a shared layout if the camera was replaced. Fixed.$$$All windows displayed the same timestamp after a previe
Nx Witness Client x64 Version 5.1.4.38659
Release Date
5/7/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

5.1.4.38659 Video Management System$$$PUBLISHED 07 May 2024$$$Release Notes:$$$These release notes cover improvements; bug fixes; and expanded device support deployed compared to the latest minor release (5.1.3).$$$BREAKING CHANGES:$$$Support for Microsoft Windows 8.1 and Microsoft Windows Server 2012 will be discontinued in the next major release (6.0/Gen6).$$$GENERAL IMPROVEMENTS:$$$Improved support for Nvidia T1000 graphics cards in multiple monitor; multiple tile configurations.$$$ANALYTICS IMPROVEMENTS and FIXES:$$$Event Post-Recording time did not correspond to the value specified in the Event rule. Fixed.$$$VCA analytics is enabled on Videosec cameras.$$$If the recording schedule was not set on a device; object search was unable to find some objects. Fixed.$$$The Objects Tab was not shown when the Sample Plugin was enabled. Fixed.$$$The Rules engine would reset the chosen Object Type for the Analytic Object Detected event. Fixed.$$$Event Rules Engine did not allow setting a pre- and post-recording time for one-time; fixed duration Events. Fixed.$$$If “Declare additional event types” was enabled on the “Stub: Events” plugin then the event types were not displayed in the Event Rules Engine. Fixed.$$$DEVICE SUPPORT AND DEVICE SPECIFIC FIXES:$$$Newly Supported Devices:$$$Provision ISR DMA-340IPENx$$$Karel NBE-454Zu-25$$$Hikvision DS-2TD4237$$$Encoders added to the analog list:$$$Winic AR324x DVR$$$Dahua N84B5N; N82B3P$$$Clinton Electronics CE-E04HDA; CE-E16HDA$$$Multisensor Cameras:$$$Axis P3737PLE$$$Hikvision DS-2SE7C432MW-AEBx$$$Avigilon 32c-h5a-4mh$$$Raysharp RS-CT252N6TNB; TB2XTH36IP5$$$Advanced PTZ:$$$Hikvision DS-2TD4228-10/W$$$EUKLIS KLIS_D40X-IP-3M-IRD$$$Dahua 5A445XANR$$$i-PRO WV-S66300-Z3L;WV-S66300-Z4;WV-S66300-Z4L; WV-S66600-Z3L; WV-X86530-Z2_PTZ; WV-X86531-Z2_PTZ; WV-S66600-Z3; WV-S66700-Z3; WV-S65302-Z2; WV-S65340-Z2; WV-S65301-Z1; WV-B-S-U65300-ZY; WV-U61300-ZY; WV-S65340-Z; WV-S61501-Z1; WV-S65501-Z1; WV-S61302-Z4$$$Device Specific Fixes:$$$If the Allow System to optimize camera settings option was disabled; stream profiles were still created on Axis cameras. Fixed.$$$Camera profile (stream resolution) was not properly handled on Axis analog cameras. Fixed.$$$Bosch FLEXIDOME 5100i IR object Vehicle received as unknown. Fixed.$$$Provision ISR DMA-340IPEN-28 duplicated primary stream. Fixed.$$$On Milesight cameras; the Desktop Client notifications triggered by camera events could have incorrect timestamp. Fixed.$$$On Sharp YK-P02AG; Server configured the low-resolution stream as the primary one; and did not configure the secondary stream. Fixed.$$$DAHUA DHI-VTO2202F-P could not be discovered manually. Fixed.$$$Some Hanwha cameras were discovered and configured through Onvif with the primary resolution lower than expected. Fixed.$$$Pelco VS1NN60 could not be discovered properly. Fixed.$$$2N SIP horn speaker entered an online/offline loop. Fixed.$$$The Axis I8116 intercom was duplicated in the Resource Tree. Fixed.$$$Alarm input and thermal sensor were not enabled for TVTH-S01-0001-BUL-G. Fixed.$$$The input signal on KO1 ITXAI CSB2-2M4P-1IMARH was not detected. Fixed.$$$CSG cameras were discovered with an incorrect vendor name. Fixed.$$$BUG FIXES:$$$In some cases; RTSP streams could enter a continuous online-offline loop after the RTSP stream goes offline. Fixed.$$$Sometimes; the Desktop Client could experience connection drops with Server when connected over a slow network. Fixed.$$$Audio could not work properly on some Edge devices when onvif_replay=true and audio were enabled. Fixed.$$$On certain cameras; the recorded footage could have playback issues when camera recording was triggered by the Analytic Object Detected trigger. Fixed.$$$Cloud systems can disconnect from the Cloud in some network environments. Fixed.$$$A locked Video Wall can be closed from the Desktop Client. Fixed.$$$Cross-System Layout that contained items from different Systems could close in case of the cloud connection interruption. Fixed.$$$The Desktop Client allowed repla
Nx Witness Client x64 Version 5.1.3.38363
Release Date
3/11/2024
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

Nx Witness v5.1.3.38363$$$(PUBLISHED 11 Mar 2024)$$$ $$$$$$BREAKING CHANGES AND KNOWN ISSUES:$$$Mobile Clients 22.4 and prior are incompatible with VMS 5.1.x.$$$Support for Microsoft Windows 8.1 and Microsoft Windows Server 2012 will be discontinued soon. Minimum Microsoft OS version for Gen6 will be Windows 10 / Server 2016.$$$ $$$$$$IMPROVEMENTS:$$$The Desktop Client stability improved for laptops with Mac M2 processors.$$$If Cloud is unstable; currently connected Cloud users would be disconnected from their systems after 10 minutes. Now the timeout is increased to 6 hours.$$$Cloud Merge is much more stable in the environments with a poor connection between Servers.$$$Server stability improved (crashes / memory leaks fixed).$$$ $$$$$$ANALYTICS IMPROVEMENTS/FIXES:$$$The Desktop Client on Microsoft Windows 11 and Ubuntu 22.04 incorrectly displayed analytic objects captured by a camera. Fixed.$$$ $$$$$$NEW DEVICE SUPPORT/IMPROVEMENTS/FIXES:$$$High-res and Low-res streams were mixed up on the Dahua DHI-VTO2202F-P camera and the Dahua DHI-VTO2101E-P-S2 intercom. Fixed.$$$Alarm input events are now supported for TRUVISION TVTH-S01-0001 series$$$Alarm input events are now supported for Hikvision DS-2CD2326G2; Hikvision DS-2CD2347G2H$$$Axis P1468 and M3216 were duplicated during auto-discovery. Fixed.$$$Encoders added to the analog list:$$$DW ENC4K16$$$Dahua N54B5N added to resource data to enable encoder license usage. Fixed.$$$Hikvision DS-7604NXI-K1 NVR added as an encoder. Fixed.$$$Advanced PTZ:$$$Saved positions and tours did not work for Bosch Autodome 5000 camera. Fixed.$$$i-PRO WV-S61301-Z2; WV-U65301-Z1 WV-B61301-Z1; WV-B61300-ZY; WV-B65301-Z1; WV-S61300-ZY.$$$EUKLIS KLIS D36X-IP-UDV-IR500-V$$$Multisensor cameras:$$$Truvision TVTH-S01-0002-BUL-G$$$Dahua DHI-TPC-DF1241x; DHI-TPC-BF5441x; DH-TPC-BF2120$$$Axis f44x; f9114; P4707x; P4705x$$$ $$$$$$HANWHA DEVICES SUPPORT/IMPROVEMENTS/FIXES:$$$The Server reported false positive network issues with the Hanwha Multi-sensor cameras. Fixed.$$$The option to disable audio has been added on Hanwha intercoms settings.$$$Add support for Hanwha SPC-2001 joystick.$$$Optimized CPU usage when performing analytics on Hanwha Edge devices.$$$ $$$$$$BUG FIXES:$$$PTZ tour could stop when a user opened another camera on the Desktop Client. Fixed.$$$If the Motion tab (on the right panel) had been activated by a Hotkey in the Desktop Client; it was displayed by default after restart (instead of the Notifications tab). Fixed.$$$Video playback speed would slow and then increase when switching between layouts. Fixed.$$$The SOAP header was missing for some Server requests. Fixed.$$$After upgrading to 5.1.0; the Bookmark Log search did not display bookmarks created in version 5.0. Fixed.$$$The layout background image did not show up in the Video Wall mode. Fixed.$$$LDAP user failed to authenticate when opening a new window from the Desktop Client. Fixed.$$$The recorded footage was updated with the significant delay while the cursor was dragged over the timeline. Fixed.$$$The microphone icon was disabled in the Desktop Client when using redirected two-way audio. Fixed.$$$The Camera does not support PTZ message was incorrectly displayed when controlling a de-warped fisheye camera with a joystick. Fixed.$$$In rare cases if a Server had more than one storage and they shared the same file location; they were reported as disabled on the Desktop Client and reserved on Web Admin upon server restart. Fixed.$$$If using Cross-System Layouts; the Server could become unresponsive after some time when running on port 7001. Fixed.$$$The in-client browser could not process the login screen for some web applications that requested certain permissions (i.e. “Enable Desktop Notifications”). Fixed.$$$Starting 5.1.2; the exported video with timestamps had incorrect length (shorter). Fixed.$$$ $$$$$$API/SDK CHANGES/FIXES:$$$Added the maxAnalyticsDetailsDurationS parameter to analyticsLookupObjectTracks.$$$The result description for /ec2/analyticsLookupObjectTracks was added to the API
Nx Witness Client x64 Version 5.1.2.37996
Release Date
12/20/2023
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

Nx Witness v5.1.2.37996$$$(PUBLISHED 20 Dec 2023)$$$ $$$$$$IMPROVEMENTS:$$$Improved MITM protection for Server to Server communication.$$$Cloud Merge improved for some specific network configurations.$$$ $$$$$$ANALYTICS IMPROVEMENTS/FIXES:$$$The Server experienced additional memory load in case of an analytics event search involving a query for data that contained a lot of text. Fixed.$$$Intrusion detection on Hikvision DS-2CD2346G2-I was not detected. Fixed.$$$Analytics objects search improved.$$$Bosch IVA analytic events were not triggered. Fixed.$$$Vivotek ANPR submenu was not displayed under the Plugin page. Fixed.$$$Boundary boxes and Attribute information disappeared too fast while viewing the stream from Dahua cameras. Fixed.$$$ $$$$$$NEW DEVICE SUPPORT/IMPROVEMENTS/FIXES:$$$Axis:$$$?1210; C1211; C1510; C2005; and C8110 were recognized as cameras or I/O modules; instead of horn speakers. Fixed.$$$C1310E/C1211E went offline after updating to AXIS OS 11. Fixed.$$$Axis Q1656-DLE took an incorrect resolution for the second channel (radar). Fixed.$$$Hikvision:$$$DS-7332HUI-K4 did not stream any video. Fixed.$$$Not all channels for Hikvision 7216HUHI were added. Fixed.$$$DS-2CD2387G2-LSU/SL and iDS-2CD7146G0-IZS now support signal input alarm.$$$On Hikvision cameras; the DST settings did not apply when the Server tried to change camera time. Fixed.$$$Added support for IDView iv-de2812cll5mp-ca; iv-8mp180de; iv-def28cll5mp-lt$$$Bositaly BS-IPT4505G3MZx had the alarm output inverted. Fixed.$$$Vivotek MA9321-EHTV did not display all channels. Fixed.$$$FLIR FC-644 series cameras will use Onvif.$$$The Detect motion during archive import option was wrongfully available on many cameras. Fixed.$$$Sharp YK-P02AG reported the low-resolution stream as the primary one. Fixed.$$$Encoders added to the analog list:$$$Uniview vs8100-v2; xvr302$$$Advanced PTZ:$$$MS-C5371-X12$$$TRUEN TX-P5N840N20R$$$I-Pro wv-b65302-z1/z2 and wv-s61301-z1/z2$$$Panasonic wv-s6530$$$Dahua dh-sd5a432xb-hnr and sd5a445Xa-hnr$$$Vivotek vs8100-v2 PTZ issues are fixed.$$$Multisensor cameras:$$$Avigilon 12W-H3-4MH-DP1-B$$$Hikvision ids-2cd8a46g0-xzhsy; ds-2td4167x; ds-2td4167-50/wy; iDS-2CD7146G0-IZS$$$I-Pro wv-s8543x; wv-s8544x; wv-s8563x; wv-s8564l; wv-s8573x; wv-s8574x; wv-x86531-z2x; wv-x86530-z2x; wv-s85702-f3l; wv-s85402-v2l; wv-u85402-v2l$$$Truvision tvth-s01-0001-tur-g$$$VCA ipai96a10-rf; ipai97a20-mr; ipai98a05-q56$$$ $$$$$$HANWHA DEVICES SUPPORT/IMPROVEMENTS/FIXES:$$$Hanwha Multi-sensor cameras had RTP packet issues since 5.1. Fixed.$$$Hanwha Edge: memory consumption optimized.$$$Zip signatures added to SolidEdge zip update package.$$$ $$$$$$BUG FIXES:$$$The Desktop Client could not be launched properly with the “--acs” command line option (this was used in Paxton integrations). Fixed.$$$The Desktop Clients adaptive scaling did not switch correctly when the CPU reached 100%. Fixed.$$$The Desktop Client on Windows could hang when searching through a large number of bookmarks created by analytic events. Fixed.$$$”Open in a new tab” for a camera worked significantly slower in the Desktop Client. Fixed.$$$In some situations; the Server could freeze during the re-indexation. Fixed.$$$Manually added RTSP multicast stream did not work. Fixed.$$$Shared layouts did not save as expected. Fixed.$$$In some specific cases; the Server could crash after updating from 5.0 to 5.1.x. Fixed.$$$In case of a merged system; Servers the user was not connected to could go offline. Fixed.$$$Cameras with the RTSP Ports previously changed; were displayed as offline. Fixed.$$$Fixed the Incorrect Replaced camera discovered notification.$$$Cloud connection was failing after the Server port was changed in WebAdmin or Cloud Client. Fixed.$$$The events were not triggered if a certain camera was selected in event options. Fixed.$$$The Sync button on the Timeline switched to disabled after a current layout was saved through the Save Layout as... Main Menu item. Fixed.$$$Saved layouts opened with the Sync button disabled after reconnecting to the
Nx Witness Client x64 Version 5.1.1.37512
Release Date
9/18/2023
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

Nx Witness v5.1.1.35712 (September 18; 2023)$$$$$$BREAKING CHANGES AND KNOWN ISSUES:$$$Mobile Clients 22.4 and older are not compatible with VMS 5.1.$$$IMPROVEMENTS:$$$The load time on large systems is significantly improved.$$$Added the HID packet investigation tool for unknown joysticks on MacOS.$$$Improved the discovery mechanism on Edge servers.$$$The link to the User Manual is added to the Main Menu.$$$ANALYTICS IMPROVEMENTS/FIXES:$$$Hykon analytics plugin introduced. The following devices are supported:$$$ITCO502713ZW$$$ITCV402713ZW$$$ITCO402812ZW$$$ITCV4028FW$$$ITCX5028FW$$$ITCP502713ZW$$$ITCP402812ZN$$$ITCP802713ZW$$$ITCX8028FW$$$ITCY402812ZW$$$ITCX4028FW$$$ITCS502812ZW$$$ITCS4025XW$$$ITCO802812ZW$$$ITCB40WAFN$$$ITCM4028FW$$$ITCO402812ZN$$$Dahua analytics plugin:$$$Smart motion detection events for Dahua analytic cameras were not listed as supported. Fixed.$$$NEW DEVICE SUPPORT/IMPROVEMENTS/FIXES:$$$New Supported Devices:$$$Axis C1211 speaker$$$AXIS C8110 Network Audio Bridge$$$Dahua IPC-HFW5241E-Z12E$$$XR cameras (Dahua OEM)$$$Multi-sensor cameras:$$$TruVision TVTH-S01-0002-BUL-G$$$Axis P4707PLVE/AXISP4705PLVE$$$Alibi ali-pf40-lua$$$Annke i51ec$$$Arecont Vision av20576dn$$$AXIS p4705-plve; p4707-plve; axisq8742le$$$CPro (DW) nvm5-520; nvm6-732; nvm9-720-r$$$Dahua dh-ipc-pdw5849-a180-e2-aste; dh-psdw5631sp-b360-e4-d204-dc12;$$$DW dwc-pds10wi28a$$$EmpireTech ipc-color4k-t180$$$ENS Security sipsp8masbr/4-u2$$$Hikvision ds-2cd2346g2p-isu/sl; ds-2cd2347g2p-lsu/sl; ds-2cd2367g2p-lsu/sl; ds-2cd6d42g0-is; ds-2cd3387g2p-lsu/sl; ds-2se4c425*; ds-2se7c432mwg-eb/26; gnc348g2p-xdlu/sl$$$Hinovision ipc7pt5326$$$I-Pro wv-s8564l; wv-s8573l; wv-x86530-z2_multi$$$IC Realtime ipel-dl80f-irw1$$$Inaxsys insmdo42irwf$$$Illumivue ilv-ip4bdl-nl$$$Invid vis-p4multi160-wl$$$LTS cmip3c6pw-28sdl$$$Mobotix d16d-sec$$$Montavue mt2d4-ir-ai-smd3-w$$$Pelco imd20136$$$Reolink Trackmix poe$$$TruVision TVTH-S01-0002-BUL-G$$$Turing tf-ams5av2$$$Uniview uv-ipc2k24se-adf40kmc-wl-i0$$$Univiewtec ipb4180x$$$VCA zn1a-2d6dtmz71$$$Vivotek ms9390-ehv-v2$$$Advanced PTZ support:$$$GeoVision GV-SD4834x$$$Milesight NC8241-X36x$$$Uniview IPC3234SR3-DVZ28; IPC6424SR-X25-VF;$$$Encoders added to the analog list:$$$Admiral adm8p8-v3r$$$Aibase nvr-3216-16p-ai$$$Alibi ali-nr161p-4; nvrh1604-0$$$Bolid rgg-1622$$$Brickcom wvs-01ap$$$Bst Security bst-aox9008$$$Capture r2-16chnvr4t$$$Dahua dh-nvr4432-4k; dh-nvr1104hc-hds4; dh/hcvr5104hs-v6/-af-dvr-ii-a/4-1; dhi-nvr5232hs-4ks2; dhi-nvr1104hs-s3/h; x54a5l4; n42b3p; n54b5n;$$$DataMan rs-dm-470a$$$Dvtel en-204$$$ENS Security xvr504l-32-i3; xvr501h-16-4kl-i3; nvr504l-32/16p-4ks2e$$$Eve 4x4 v2$$$Evision PRODVR 5xx; 8xx$$$GW Security gw-4108enp; gw5532nsn$$$Hikvision ds-7116hghi-f1/n; ds-7308hghi-sh; ds-9032hui-k8; ds-96256ni-i24; ds-8832n-r8; ds-96128ni-i24/h; ds-mp5604n; dvr-204u-k1; ids-7208hqhi-m1x; ids-7204hqhi-m1x; ids-9664nx-i8x$$$Honeywell hen081x4; hen163x4; hen162x4; hen321x4; hen322x4; hen642x4; hen643x4; hrht404x; hrht408x; hrhq116x; hrht416x$$$IC Realtime nvr-el16-2u12mp1$$$Illumivue ilv-nvr4x$$$Infinova v3073-08j02$$$Interlogix tvr1516x$$$IVSecurity nr004xa$$$Jovision jvs-nd7932-hv$$$Lorex n861d6; n883a3$$$LTS ltd8316m-et; ltd8424k-ea; ltn8816k;$$$Luma Surveillance™ 500 Series DVR$$$Lumens oip-n60d$$$Mazi hsvr-16ht$$$Norden Communication enr-16032-n-usk$$$NVR Premium unr3088-64$$$Reolink rln8-410$$$Revo America ru16nvr2b-1; rup32nvr1a$$$Rister ul-dvr302-8z$$$Rvi 1hdr16l(a)$$$Scoo sc-n116p-h2$$$Seyeon Tech fws200-01p$$$Shenzhen h.26x encoder$$$Swann nvr16-8580rn$$$Turing tr-mrp042t$$$TVT td-9554e3b$$$Uniview nvr302-16e-p16-b-nb; nvr501-04b-lp4; nvr-104lx-p4; hnr161$$$USAVision (GeoVision) ua-xvl1610$$$VIP Vision c87_nvr16pro7$$$Vista CCTV va-dvr1605mp$$$Winic ar324-8/k2; ar526-32$$$X-Security xs-nvr3232-4k$$$Noname:$$$amn-95216-4ks2$$$b18_nvr8pro6$$$ern-0421hs-p$$$rs-n7816ha-pr-e$$$n8208$$$sc-n104p-h1$$$ssr621q-nand$$$tcm-xvr1b16-i (Dahua xvr1b16-i OEM)$$$i7-t2508uhv$$$hds-7216tvi-hdmi/fn$$$Fixed alarm output on Bositaly BS-IPTx cameras.$$$Forced Onvif on Arecont Vision AV20576.$$$Tp Link / Reolink RLC-823A did not have PTZ capability. Fixed.$$$Co
Nx Witness Client x64 Version 5.1.0.37133
Release Date
6/28/2023
Bug Fix?
Yes
Minor Release?
Yes
Patch Notes

Nx Witness v5.1.0.37133 (June 28th; 2023)$$$$$$BREAKING CHANGES AND KNOWN ISSUES:$$$$$$ Support for Windows 8.1 will be discontinued in the next release. Systems on Windows 8.1 may not be able to update to the next release.$$$ Mobile 22.4 is not compatible with VMS 5.1.$$$ Support for Ubuntu 16.04 was discontinued.$$$ Support for macOS 10.14 and 10.15 were discontinued.$$$$$$OPERATING SYSTEMS/PLATFORMS:$$$$$$ Added Ubuntu 22.04 support.$$$ Added MacOS 13 support.$$$$$$NEW FEATURES:$$$$$$ Cross-system layouts:$$$ Added the ability to view cameras/devices from different Cloud systems on a single layout.$$$ Such layouts can only be displayed in the Desktop Client.$$$ Cloud users can set up and save such layouts but cannot share them to other users.$$$ Cross System layouts cannot be used with VideoWall; Showreels or automated with Rules.$$$ Camera replacement:$$$ It is now possible to replace a camera with another camera from the same server.$$$ Name; archive; general and advanced settings; recording settings; PTZ settings; event rules; analytics and camera access rights will be transferred to a new camera.$$$ Motion Detection settings; 2-way Audio will not be transferred.$$$ The current archive from the old camera will still be accessible.$$$ This action can be undone only when the old camera goes back to online state and Server discovers it.$$$ Camera replacement can be done only by Owner and Administrators.$$$ Camera replacement is not supported for:$$$ Virtual cameras$$$ Speakers$$$ NVRs$$$ IO modules$$$ Multi-sensor cameras$$$ Unauthorized cameras$$$ Offline cameras that appear after reindexing the archive.$$$ Added a possibility to download the Desktop Client and Server logs remotely (System Administration -> Logs Settings). Users can configure logging and download logs.$$$ Added a possibility to choose the specific ONVIF profile for cameras (the “Expert” tab). The ONVIF profile list is determined ONLY when adding the camera to the server. If reconfigure ONVIF profiles afterwards (on the camera itself); they will not be reflected in the Desktop Client.$$$$$$IMPROVEMENTS:$$$$$$ Min/Max archive retention period is in minutes; hours and days now.$$$ Motion DB was moved from the system storage to the archive storage.$$$ Server connections to/disconnections from the Cloud are now logged in the Audit Trail.$$$ Added a power management setting that allows computers to sleep while the Desktop Client is still open.$$$ Showreels no longer display a title bar on top with the camera name.$$$ Scheduled database backup has been disabled by default on ARM devices.$$$ Added support for MPEG4 RTSP video streams.$$$ Bookmarks and object attributes could be found only if a text matched the one from the beginning of the word. Now search can be performed by a text in the middle of the string (3 symbols minimum).$$$ Specific ports for viewing a Camera web page can be redefined on the “Expert” tab in Camera settings.$$$ The Do HTTP request action now supports PATCH requests again (this was possible in 4.2; but due to API upgrade was not implemented in 5.0).$$$ The Use source camera option is added to all camera-related actions.$$$ The sound duration for the “Play Sound” and “Repeat Sound” actions was increased from 10 to 30 seconds.$$$ The maximum value for LogicalID is set to 999999.$$$ Added a new system notification that local storage is being used for analytic and motion data.$$$ Mobile user manual was added to the desktop client installation package.$$$ The “Show text overlay” action can show more text.$$$ Now users with the Administrator role can initiate the “Create Backup” and “Restore Backup” operations. The “ownerApiForAdmins” Server configuration option is introduced and available in Webadmin (advanced options; default value is false). ATTENTION! This i